Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
รายการ #: 144239335

Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes

รายการ #: 144239335

THB 6692

Price Details

Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )

*All items will import from สหรัฐอเมริกา

มีสินค้า
สหรัฐอเมริกา นำเข้าจาก USA ร้านค้า

QTY:

สั่งซื้อตอนนี้และรับสินค้าประมาณ วันศุกร์, กรกฎาคม 10
พันธมิตรด้านโลจิสติกส์ชั้นนำของเรา
  • fedex
  • dhl
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
การรับประกัน U-Care:
ไม่มี
เลือกแผน
fast shipping

Fast
Shipping

free return

คืนสินค้าฟรี*

แพ็คสินค้าอย่างปลอดภัย

แพ็คสินค้าอย่างปลอดภัย

สินค้าแท้ 100%

สินค้าแท้ 100%

pci-dss

PCI DSS Compliance

iso certified

ISO 27001 Certified


paypal payment
visa payment
mastercard payment
american express payment
bank transfer thailand payment
k plus payment
cenpay payment
boonterm kiosk payment
thai qr payment
big c payment
true money wallet payment
rabbit line pay payment
Note: Step Down Voltage Transformer required for using electronics products of สหรัฐอเมริกา store (110-120). Recommended power converters ซื้อเลย.

จุดเด่น

Enhanced Accuracy
TISAB II incorporates CDTA, improving the precision of fluoride measurements with ion-selective electrodes, effectively addressing common interference issues faced in conventional testing methods.
User-Friendly
Designed for simplicity, TISAB II allows laboratories and researchers to easily prepare and use the buffer, streamlining the process for consistent and reliable fluoride analysis.
Versatile Application
Ideal for a wide range of analytical environments, TISAB II supports various fluoride testing needs, making it the preferred choice for environmental, clinical, and industrial applications.

รายละเอียดสินค้า

Shop Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes online at a best price in ประเทศไทย. B0043EVKGC
Item Weight1.5 lbs (680 grams)

เหมาะสำหรับใคร?

Suitable For
  • Laboratory Technicians

    Essential for technicians conducting fluoride analysis using ion selective electrodes in various laboratory environments.

  • Environmental Scientists

    Ideal for scientists assessing water quality and fluoride concentrations in environmental samples and field studies.

  • Academic Researchers

    Beneficial for researchers in academia performing experiments related to fluoride chemistry and ion analysis.

Not Suitable For
  • Home Users

    Not suitable for casual users without specialized knowledge or equipment for fluoride testing at home.

  • Non-technical Professionals

    May be overwhelming for professionals lacking technical expertise in ion selective electrode usage and chemical analysis.

  • Small Scale Applications

    Not recommended for small, infrequent tasks where comprehensive fluoride analysis techniques are unnecessary.

ข้อมูลผลิตภัณฑ์

Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes

มีข้อสงสัย? คุยกับเรา

คําถามและคําตอบของลูกค้า

  • คำถาม: What is TISAB II and its role in fluoride analysis?

    คำตอบ: Total Ionic Strength Adjustment Buffer (TISAB II) is a specialized buffer solution used to stabilize ionic strength during fluoride analysis with ion-selective electrodes. It ensures accurate readings by maintaining consistent ionic conditions, which is crucial for the reliability of fluoride measurements in various samples, such as drinking water or biological fluids. The presence of CDTA in TISAB II enhances its effectiveness by binding with interfering metal ions, providing clearer and more precise analysis outcomes.
  • คำถาม: How do I use TISAB II with ion-selective electrodes?

    คำตอบ: To utilize TISAB II effectively, first prepare your sample by diluting it as necessary, then add TISAB II in a defined ratio. This mixture can be directly introduced to an ion-selective electrode designed for fluoride detection. The buffer's function is to control ionic strength and minimize interferences, which is vital for obtaining precise and reproducible fluoride concentration readings in environmental samples or clinical assessments.
  • คำถาม: What are the main components of TISAB II?

    คำตอบ: TISAB II primarily consists of a blend of buffers that stabilize pH and ionic strength, along with CDTA, which is a chelating agent that binds metallic ions. This combination enhances the accuracy of fluoride detection by minimizing the effect of contaminants and competing ions in the sample. By ensuring that the analytical conditions are consistent, TISAB II plays a key role in various applications, from water quality testing to food safety analysis.
  • คำถาม: Why is CDTA included in TISAB II?

    คำตอบ: CDTA, or trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid, is included in TISAB II to enhance the buffer’s ability to remove potential interference from metal ions. These ions can adversely affect the performance of the ion-selective electrode used for fluoride analysis. By binding with these interfering species, CDTA helps in obtaining more reliable and accurate fluoride concentration measurements, which is particularly important in regulatory compliance and research scenarios.
  • คำถาม: Can TISAB II be used for other ions aside from fluoride?

    คำตอบ: While TISAB II is primarily designed for fluoride analysis, its buffered system can be adapted for other ions that require significant ionic strength adjustments. However, its specificity and the effectiveness of CDTA may not be the same for every ion type. Researchers often use TISAB II in conjunction with the appropriate ion-selective electrodes tailored for the specific analyte being tested, ensuring reliable readings in various analytical contexts.
  • คำถาม: What is the recommended storage condition for TISAB II?

    คำตอบ: TISAB II should be stored in a cool, dark place, ideally at room temperature, to maintain its integrity. It is important to keep the buffer away from direct sunlight and extreme temperatures, which can degrade the solution over time. Proper storage ensures that the buffer maintains its optimal pH and ionic strength, crucial for accurate fluoride analysis when utilized in testing laboratories or field applications.
  • คำถาม: How does TISAB II affect the pH of a sample?

    คำตอบ: TISAB II is formulated to maintain a neutral pH, typically around 5.0 to 5.5, which is ideal for fluoride measurements. Adding TISAB II to a sample helps to regulate its pH, crucial for ensuring that fluoride exists in a stable, measurable state. This controlled pH environment is essential in achieving accurate calibrations and results, especially in water quality assessments or food analysis, where pH can fluctuate significantly.
  • คำถาม: Is TISAB II compatible with all ion-selective electrodes?

    คำตอบ: TISAB II is primarily used with ion-selective electrodes designed specifically for fluoride detection. However, compatibility can vary based on the electrode’s chemistry and design. It is advisable to consult the manufacturer’s guidelines for specific electrodes to ensure they are suitable for use with TISAB II. This compatibility check is particularly essential to avoid erroneous readings in scenarios like environmental monitoring or product testing.
  • คำถาม: What types of samples can be analyzed using TISAB II?

    คำตอบ: TISAB II can be used to analyze a broad range of samples, including drinking water, wastewater, food products, and biological samples such as saliva or serum. Each sample type may require specific preparation steps, such as dilution prior to adding TISAB II, to ensure that fluoride concentration can be accurately quantified. This versatility makes TISAB II invaluable in laboratories working on environmental, health, or safety assessments.
  • คำถาม: Where can I buy Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes in Thailand?

    คำตอบ: You can purchase Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes at Ubuy. Ubuy offers a wide selection of chemical products and laboratory supplies, making it a reliable source for your analytical needs in Thailand. The platform provides easy access to institution-quality reagents perfect for both professional and academic use.

RiccaChemical Electrodes Editorial Review

ไม่พบบทวิจารณ์ด้านบรรณาธิการ

ความคิดเห็นและคะแนนจากลูกค้า

5.0
1 การให้คะแนนของลูกค้า
  • 5 ดาว
    100%
  • 4 ดาว
    0%
  • 3 ดาว
    0%
  • 2 ดาว
    0%
  • 1 ดาว
    0%

แบ่งปันความคิดของคุณกับลูกค้าท่านอื่น

แชร์ความคิดของคุณกับลูกค้ารายอื่น

ประวัติราคาสินค้า

ข้อมูลสำคัญ

  • ข้อจำกัด : สำหรับผลิตภัณฑ์ที่จัดส่งระหว่างประเทศ โปรดทราบว่าการรับประกันของผู้ผลิตอาจไม่ถูกต้อง ตัวเลือกบริการของผู้ผลิตอาจไม่สามารถใช้ได้ คู่มือผลิตภัณฑ์ คำแนะนำ และคำเตือนด้านความปลอดภัยอาจไม่เป็นภาษาของประเทศปลายทาง ผลิตภัณฑ์ (และวัสดุประกอบ) อาจไม่ได้รับการออกแบบตามมาตรฐาน คุณลักษณะเฉพาะ และข้อกำหนดเกี่ยวกับการติดฉลากของประเทศปลายทาง และผลิตภัณฑ์อาจใช้แรงดันไฟฟ้าไม่สอดคล้องกับของประเทศปลายทางและมาตรฐานทางไฟฟ้าอื่น ๆ (ต้องใช้อะแดปเตอร์หรือตัวแปลงไฟตามความเหมาะสม) ผู้รับมีหน้าที่ตรวจสอบให้แน่ใจว่าสินค้าสามารถนำเข้าประเทศปลายทางได้อย่างถูกกฎหมาย เมื่อสั่งซื้อจาก Ubuy หรือตัวแทนจำหน่าย ผู้รับคือผู้นำตามกฎหมาย และต้องปฏิบัติตามกฎหมายและระเบียบข้อบังคับทั้งหมดของประเทศปลายทาง
  • ผลิตภัณฑ์บางรายการใน Ubuy ไม่ได้มีไว้เพื่อขาย เนื่องจาก Ubuy เป็นเครื่องมือค้นหาระดับโลก ผลิตภัณฑ์อยู่ภายใต้กฎระเบียบด้าน การส่งออก/การค้า